Validation Log 2025-12-14 22:30:16.292416 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001454/mwtab/txt Study ID: ST000892 Analysis ID: AN001454 File format: txt Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 0 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value for the subsection, "SPECTROMETER_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['MHz']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "POWER_LEVEL", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "RECEIVER_GAIN", in the "NM" section should be a unitless number. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "OFFSET_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "PRESATURATION_POWER_LEVEL", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "TEMPERATURE", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "32 | 32 | 32 | 32 | 32 | 32 | 32 | 32", for the subsection, "NUMBER_OF_SCANS", in the "NM" section should be a unitless number. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "ACQUISITION_TIME", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "4 s | 4 s | 4 s | 4 s | 5 s | 6 s | 7 s | 8 s", for the subsection, "RELAXATION_DELAY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "NUM_DATA_POINTS_ACQUIRED", in the "NM" section should be a unitless number. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "LINE_BROADENING", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY".