Validation Log 2025-12-14 22:45:54.684642 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001737/mwtab/txt Study ID: ST001062 Analysis ID: AN001737 File format: txt Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 7 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "Negative", for the subsection, "IONIZATION", in the "MS" section should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: Unknown or invalid subsection, "ACQUISITION_DATE", in the "MS" section . Error: The value, "45", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "5uL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", for the subsection, "TARGET_SAMPLE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "quantified m/z" column at position 3 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "InchiKey" column at position 6 in the METABOLITES table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The 2nd "Adduct" column at position 5 in the METABOLITES table, matches a standard column name, "adduct". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "rtimes(mins)" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Adduct" column at position 2 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The 2nd "Adduct" column at position 5 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: There are duplicate column names in the METABOLITES table.