Validation Log 2025-12-14 22:46:42.963219 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001753/mwtab/txt Study ID: ST001071 Analysis ID: AN001753 File format: txt Status: Contains Validation Issues Number of Issues: 19 Number of Warnings: 3 Number of Value Errors: 15 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: The value, "30 days and 50days", for the subsection, "TREATMENT_DOSEDURATION", in the "TREATMENT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: The value, "2.4", for the subsection, "HELIUM_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mL/min']. Ignore this when more complicated descriptions are required. Error: The value, "230", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "69.9", for the subsection, "IONIZATION_ENERGY", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['eV']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "2.4ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "split (5:1), 1ul", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "250C", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "1094 emvolts", for the subsection, "RUNNING_VOLTAGE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "10ul", for the subsection, "STRONG_WASH_VOLUME", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "10ul", for the subsection, "SAMPLE_SYRINGE_SIZE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: There are duplicate samples in the MS_METABOLITE_DATA section. Warning: The "refmet_name" column at position 2 in the METABOLITES table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "REGNO" column at position 5 in the METABOLITES table, matches a standard column name, "mw_regno". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.