Validation Log 2025-12-14 22:46:45.898717 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001754/mwtab/txt Study ID: ST001072 Analysis ID: AN001754 File format: txt Status: Contains Validation Issues Number of Issues: 21 Number of Warnings: 15 Number of Value Errors: 16 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "FLOW_RATE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: The "InGel_#1" column at position 2 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#3" column at position 4 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#4" column at position 5 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#5" column at position 6 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#6" column at position 7 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#7" column at position 8 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#8" column at position 9 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#9" column at position 10 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#10" column at position 11 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#11" column at position 12 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#12" column at position 13 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_#13" column at position 14 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_I" column at position 23 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_N" column at position 28 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "InGel_P" column at position 29 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.