Validation Log 2025-12-14 22:48:33.772417 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001791/mwtab/txt Study ID: ST001102 Analysis ID: AN001791 File format: txt Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 3 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "600µL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "65°C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1.67µL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "500-1000bar", for the subsection, "COLUMN_PRESSURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: The "quantified m/z" column at position 4 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "InChI Key" column at position 2 in the METABOLITES table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "rtimes (mins)" column at position 5 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.