Validation Log 2025-12-14 22:49:01.729817 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001802/mwtab/json Study ID: ST001108 Analysis ID: AN001802 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 1 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected in ["PROJECT"]["PHONE"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["STUDY"]["PHONE"]. A legitimate value should be provided for this required key. Error: The value, "Gestational days 125-birth", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "2824.2", in ["NM"]["OFFSET_FREQUENCY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "6.41E-05", in ["NM"]["PRESATURATION_POWER_LEVEL"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['W', 'dB']. Ignore this when more complicated descriptions are required. Error: The value, "4C", in ["NM"]["TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "1.8173", in ["NM"]["ACQUISITION_TIME"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s']. Ignore this when more complicated descriptions are required. Error: The value, "4 sec", in ["NM"]["RELAXATION_DELAY"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: The value, "1", in ["NM"]["LINE_BROADENING"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['Hz']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "CHROMATOGRAPHY". Warning: The "KEGG ID" column at position 2 in the ["NMR_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.