Validation Log 2025-12-14 22:51:33.356184 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001877/mwtab/json Study ID: ST001142 Analysis ID: AN001877 File format: json Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 6 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["COLUMN_NAME"]. A legitimate value should be provided for this required key. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "FLOW_RATE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "Mass range 1" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Mass range 2" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "HMDB ID" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "hmdb_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "HMDB ID" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "hmdb_id", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 32 MXP000013 Warning: The "rtimes" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "OV90_OVARY" column at position 157 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.