Validation Log 2025-12-14 22:54:24.621975 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001936/mwtab/json Study ID: ST001171 Analysis ID: AN001936 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 0 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "30-60", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "275 oC", in ["MS"]["CAPILLARY_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "N2", in ["MS"]["COLLISION_GAS"] should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "45 arbitary unit", in ["MS"]["DRY_GAS_FLOW"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "325 oC", in ["MS"]["DRY_GAS_TEMP"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "45 arbitary unit", in ["MS"]["GAS_PRESSURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'psig', 'bar', 'kPa']. Ignore this when more complicated descriptions are required. Error: The value, "325 oC", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "325 oC", in ["MS"]["SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid subsection, "ACQUISITION_DATE", in ["MS"]. Error: The value, "50", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "8", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required.