Validation Log 2025-12-14 22:56:23.067299 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN001989/mwtab/txt Study ID: ST001193 Analysis ID: AN001989 File format: txt Status: Contains Validation Issues Number of Issues: 24 Number of Warnings: 11 Number of Value Errors: 21 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "PROJECT" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "ADDRESS", in the "STUDY" section. A legitimate value should be provided for this required subsection. Error: The value, "pediatric samples - 0 to 3 yrs", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "250C", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "N2", for the subsection, "COLLISION_GAS", in the "MS" section should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "45", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "150C", for the subsection, "DRY_GAS_TEMP", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-4000", for the subsection, "SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value, "118ms", for the subsection, "ACTIVATION_TIME", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ms']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "MS_COMMENTS", in the "MS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "60C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Warning: The "ri" column at position 7 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "ri_type" column at position 8 in the METABOLITES table, matches a standard column name, "retention_index_type". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column pair, "ri" and "ri_type", in the METABOLITES table should have data in the same rows, but at least one row has data in one column and nothing in the other. Warning: The standard column, "other_id", was found in the METABOLITES table as "other_id". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column. Warning: The "pubchem_id" column at position 2 in the METABOLITES table has all null values. Warning: The "inchi_key" column at position 3 in the METABOLITES table has all null values. Warning: The "kegg_id" column at position 4 in the METABOLITES table has all null values. Warning: The "other_id" column at position 5 in the METABOLITES table has all null values. Warning: The "other_id_type" column at position 6 in the METABOLITES table has all null values. Warning: The "ri_type" column at position 8 in the METABOLITES table has all null values. Warning: The "moverz_quant" column at position 9 in the METABOLITES table has all null values.