Validation Log 2025-12-14 22:59:32.798679 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002037/mwtab/json Study ID: ST001224 Analysis ID: AN002037 File format: json Status: Contains Validation Issues Number of Issues: 15 Number of Warnings: 4 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: The value, "2 days after birth", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "above 1.3Kg at birth", in ["SUBJECT"]["WEIGHT_OR_WEIGHT_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["COLLECTION"]["ADDITIVES"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SAMPLE_DERIVATIZATION"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SAMPLE_SPIKING"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["COLUMN_NAME"]. A legitimate value should be provided for this required key. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "FLOW_RATE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "PubChem" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "HMDB" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "hmdb_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.