Validation Log 2025-12-14 23:00:00.013625 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002052/mwtab/txt Study ID: ST001234 Analysis ID: AN002052 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 2 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: Unknown or invalid subsection, "ACQUISITION_DATE", in the "MS" section . Error: An empty value or a null value was detected for the subsection, "INSTRUMENT_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "COLUMN_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "1 mL min-1", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50-275°C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "50°C ramped to 250°C by 12°C s-1", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: The "PubChem" column at position 2 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 3 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.