Validation Log 2025-12-14 23:00:03.313006 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002053/mwtab/txt Study ID: ST001235 Analysis ID: AN002053 File format: txt Status: Contains Validation Issues Number of Issues: 4 Number of Warnings: 1 Number of Value Errors: 3 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "250 µL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "30", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Warning: The "HMDB ID" column at position 2 in the METABOLITES table, matches a standard column name, "hmdb_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.