Validation Log 2025-12-14 23:01:06.179590 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002069/mwtab/json Study ID: ST001245 Analysis ID: AN002069 File format: json Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 7 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: The value, "60", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantitated m/z" column at position 13 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "InChIKey" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Chemical class" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "class". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem ID" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention times" column at position 15 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Ionisation mede" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "ionization_mode". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Units" column at position 12 in the ["MS_METABOLITE_DATA"]["Metabolites"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.