Validation Log 2025-12-14 23:01:04.698136 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002069/mwtab/txt Study ID: ST001245 Analysis ID: AN002069 File format: txt Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 7 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: The value, "60", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Error: Unknown or invalid section, "FACTORS". Warning: The "quantitated m/z" column at position 13 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "InChIKey" column at position 7 in the METABOLITES table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Chemical class" column at position 9 in the METABOLITES table, matches a standard column name, "class". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem ID" column at position 8 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention times" column at position 15 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Ionisation mede" column at position 5 in the METABOLITES table, matches a standard column name, "ionization_mode". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Units" column at position 12 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.