Validation Log 2025-12-14 23:02:36.024228 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002100/mwtab/txt Study ID: ST001264 Analysis ID: AN002100 File format: txt Status: Contains Validation Issues Number of Issues: 5 Number of Warnings: 0 Number of Value Errors: 4 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "Positive", for the subsection, "IONIZATION", in the "MS" section should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: Unknown or invalid subsection, "ACQUISITION_DATE", in the "MS" section . Error: The value, "65", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "3uL (negative) 5uL (positive)", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", for the subsection, "TARGET_SAMPLE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required.