Validation Log 2025-12-14 23:02:41.179135 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002102/mwtab/txt Study ID: ST001265 Analysis ID: AN002102 File format: txt Status: Contains Validation Issues Number of Issues: 16 Number of Warnings: 2 Number of Value Errors: 13 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: The value, "1 ml/min", for the subsection, "HELIUM_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mL/min']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "70", for the subsection, "IONIZATION_ENERGY", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['eV']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "60", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "57.4", for the subsection, "COLUMN_PRESSURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['psi', 'bar']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "43.67", for the subsection, "ANALYTICAL_TIME", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Error: Unknown or invalid section, "FACTORS". Warning: The "Pubchem_Derivative" column at position 2 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem ID" column at position 3 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.