Validation Log 2025-12-14 23:06:01.199040 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002162/mwtab/json Study ID: ST001298 Analysis ID: AN002162 File format: json Status: Contains Validation Issues Number of Issues: 6 Number of Warnings: 4 Number of Value Errors: 4 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "0.3 mL/minute", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantified m/z" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG ID" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention index" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "retention index" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "retention_index_type", should also exist, and that column was not found.