Validation Log 2025-12-14 23:07:29.123223 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002192/mwtab/json Study ID: ST001317 Analysis ID: AN002192 File format: json Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 4 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "250C", in ["MS"]["CAPILLARY_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "3000", in ["MS"]["CAPILLARY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "25C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantitated m/z" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Formula" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 1 C7 H7 N O2 2 C11 H13 N O3 4 C10 H9 N O2 5 C7 H7 N O2 6 C26 H43 N O5 7 C9 H9 N O3 8 C5 H9 N O3 S 11 C7 H7 N O3 12 C6 H11 N O3 14 C6 H5 N O2 15 C9 H17 N O5 16 C5 H5 N O 17 C4 H7 N O3 19 C5 H7 N O3 21 C6 H5 N O3 22 C10 H7 N O3 24 C7 H11 N O5 25 C6 H9 N O5 26 C5 H9 N O4 S 27 C8 H9 N O4 29 C10 H7 N O4 38 C7 H7 N O3 42 C28 H56 N O8 P 43 C9 H17 N O4 46 C9 H11 N O2 51 C6 H13 N O2 52 C6 H13 N O2 54 C11 H19 N O9 55 C6 H13 N O2 56 C8 H15 N O6 61 C9 H11 N O3 65 C5 H11 N O2 66 C5 H11 N O2 67 C5 H9 N O2 69 C9 H11 N O3 71 C6 H11 N O2 73 C7 H7 N O2 74 C5 H11 N O2 75 C4 H9 N O2 80 C6 H11 N O4 81 C6 H13 N O2 83 C4 H9 N O2 85 C4 H9 N O2 88 C4 H9 N O2 89 C5 H9 N O3 90 C4 H7 N O4 91 C6 H11 N O4 92 C5 H9 N O3 93 C5 H9 N O4 94 C4 H7 N O2 95 C5 H9 N O4 96 C4 H9 N O3 97 C8 H11 N O2 99 C3 H7 N O2 100 C4 H9 N O3 101 C2 H8 N O4 P 102 C3 H7 N O3 107 C5 H14 N O4 P 111 C7 H16 N O3 Warning: The "Retention times" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RTsec" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.