Validation Log 2025-12-14 23:07:32.920050 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002193/mwtab/txt Study ID: ST001317 Analysis ID: AN002193 File format: txt Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 4 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "250C", for the subsection, "CAPILLARY_TEMPERATURE", in the "MS" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-3000", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "50C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: Unknown or invalid section, "FACTORS". Warning: The "quantitated m/z" column at position 7 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Formula" column at position 2 in the METABOLITES table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 4 C10 H7 N O2 11 C7 H7 N O3 14 C8 H7 N O4 S 15 C9 H9 N O 16 C10 H9 N O3 17 C10 H7 N O4 19 C10 H7 N O3 20 C9 H9 N O3 31 C8 H15 N O3 32 C11 H13 N O3 33 C10 H11 N O 34 C7 H7 N O2 39 C9 H7 N O2 40 C10 H9 N O2 60 C26 H43 N O6 65 C26 H45 N O6 S 70 C10 H13 N O2 71 C9 H13 N O2 72 C26 H43 N O4 75 C24 H50 N O7 P 77 C26 H54 N O7 P 79 C18 H35 N O Warning: The "Retention times" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT (sec)" column at position 5 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.