Validation Log 2025-12-14 23:11:33.533137 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002272/mwtab/txt Study ID: ST001365 Analysis ID: AN002272 File format: txt Status: Contains Validation Issues Number of Issues: 17 Number of Warnings: 7 Number of Value Errors: 15 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "21-56", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "Male and female", for the subsection, "GENDER", in the "SUBJECT" section should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: The value, "125", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "800 L/h", for the subsection, "DESOLVATION_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "400", for the subsection, "DESOLVATION_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "0.3 ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "10", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: Unknown or invalid section, "FACTORS". Warning: The "m/z" column at position 2 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem" column at position 4 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention time (min)" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Sample_10139" column at position 3 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Sample_11182" column at position 25 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Sample_5550" column at position 114 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "WaterBlank33" column at position 211 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.