Validation Log 2025-12-14 23:12:07.518900 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002285/mwtab/txt Study ID: ST001369 Analysis ID: AN002285 File format: txt Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 0 Number of Value Errors: 4 Number of Consistency Errors: 0 Number of Format Errors: 4 Issue Log: Error: The value, "000000", for "PROJECT_ID" in the file header must be the letters "PR" followed by 6 numbers. Ex. "PR001405". Error: The value, "As Oven", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "250", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "280", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "FLOW_RATE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing.