Validation Log 2025-12-14 23:12:30.983215 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002293/mwtab/json Study ID: ST001373 Analysis ID: AN002293 File format: json Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 5 Number of Value Errors: 11 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "72 hours", in ["TREATMENT"]["TREATMENT_DOSEDURATION"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SAMPLE_DERIVATIZATION"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: An empty value or a null value was detected in ["SAMPLEPREP"]["SUBCELLULAR_LOCATION"]. Either a legitimate value should be provided for this key, or it should be removed altogether. Error: The value, "0.25 ml/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "30", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "5", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "20", in ["CHROMATOGRAPHY"]["ANALYTICAL_TIME"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Warning: The "quantified m/z" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem ID" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG ID" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention index" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "retention index" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "retention_index_type", should also exist, and that column was not found.