Validation Log 2025-12-14 23:13:26.607610 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002312/mwtab/json Study ID: ST001385 Analysis ID: AN002312 File format: json Status: Contains Validation Issues Number of Issues: 12 Number of Warnings: 7 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 3 Issue Log: Error: The value, "25°C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "2uL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantitated m/z" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Formula" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 7 C10 H7 N O2 15 C8 H6 O3 / C5 H10 O3 S 16 C7 H7 N O3 18 C9 H10 O4 / C8 H8 O2 19 C8 H7 N O4 S 20 C9 H9 N O 21 C10 H9 N O3 22 C10 H7 N O4 23 C10 H7 N O3 24 C9 H9 N O3 39 C8 H15 N O3 40 C11 H13 N O3 41 C7 H7 N O2 46 C9 H7 N O2 47 C10 H9 N O2 67 C26 H43 N O6 73 C26 H45 N O6 S 74 C8 H F15 O2 77 C10 H13 N O2 78 C9 H13 N O2 79 C26 H43 N O4 81 C24 H50 N O7 P 83 C26 H54 N O7 P 85 C18 H35 N O 93 C17 H34 O2/ C16 H34 O Warning: The "Adduct" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "adduct", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 18 m-H / (m+HCOO)- 40 m-H / (m+HCOO)- 93 m-H / (m+HCOO)+[-H2O] Warning: The "CAS.ID" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "cas_number". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CAS.ID" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "cas_number", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 5 498-23-7 / 97-65-4 14 124-04-9 / 626-51-7 15 611-73-4 / 4857-44-7 18 6482-98-0 / 103-82-2 26 611-71-2 / 156-38-7 40 2018-61-3 / 526-55-6 41 118-92-3 / 150-13-0 48 64339-39-5 / 57074-43-8 65 131-70-4 / 30833-53-5 92 112-80-1 / 112-79-8/ 593-39-5 93 506-12-7 / 36653-82-4 Warning: The "retention times" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT..seC-" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.