Validation Log 2025-12-14 23:15:34.480101 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002347/mwtab/json Study ID: ST001405 Analysis ID: AN002347 File format: json Status: Contains Validation Issues Number of Issues: 9 Number of Warnings: 5 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: The value, "225 ul/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "55C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantitated m/z" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Class_At_Max_Intensity" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "class". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Only_One_Class" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "class". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Adduct_At_Max_Intensity" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "adduct". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.