Validation Log 2025-12-14 23:30:37.629129 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002680/mwtab/txt Study ID: ST001638 Analysis ID: AN002680 File format: txt Status: Contains Validation Issues Number of Issues: 14 Number of Warnings: 6 Number of Value Errors: 13 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "000000", for "PROJECT_ID" in the file header must be the letters "PR" followed by 6 numbers. Ex. "PR001405". Error: The value, "4 weeks mice", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "INSTRUMENT_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "COLUMN_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "200 µL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "FACTORS". Warning: The "quantitated m/z" column at position 6 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PUBCHEM ID" column at position 2 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG ID" column at position 3 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "HMDB ID" column at position 4 in the METABOLITES table, matches a standard column name, "hmdb_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 7 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: Column(s) with no name were found in the METABOLITES table. Warning: The "" column at position 5 in the METABOLITES table has all null values.