Validation Log 2025-12-14 23:37:44.655166 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002786/mwtab/json Study ID: ST001711 Analysis ID: AN002786 File format: json Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 3 Number of Value Errors: 3 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: The required property, "FLOW_GRADIENT", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "FLOW_RATE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "COLUMN_TEMPERATURE", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_A", in ["CHROMATOGRAPHY"] is missing. Error: The required property, "SOLVENT_B", in ["CHROMATOGRAPHY"] is missing. Warning: The "quantitated m/z" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "quantitated m/z" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 4 190/116/191 Warning: The "retention time" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.