Validation Log 2025-12-14 23:39:07.167338 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN002817/mwtab/txt Study ID: ST001731 Analysis ID: AN002817 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 5 Number of Value Errors: 4 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: The value, "000000", for "PROJECT_ID" in the file header must be the letters "PR" followed by 6 numbers. Ex. "PR001405". Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "FLOW_RATE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: The "parent" column at position 3 in the METABOLITES table, matches a standard column name, "parent_moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CmpdID" column at position 2 in the METABOLITES table, matches a standard column name, "other_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "medRt" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "CmpdID" was found in the METABOLITES table, but this column implies that another column, "other_id_type", should also exist, and that column was not found. Warning: The standard column, "other_id", was found in the METABOLITES table as "CmpdID". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column.