Validation Log 2025-12-14 23:52:37.218500 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003046/mwtab/txt Study ID: ST001880 Analysis ID: AN003046 File format: txt Status: Contains Validation Issues Number of Issues: 6 Number of Warnings: 0 Number of Value Errors: 6 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "Not applicable", for the subsection, "GENDER", in the "SUBJECT" section should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the "RAW_FILE_NAME" in "Additional sample data" in entry 13 of the "SUBJECT_SAMPLE_FACTORS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the "RAW_FILE_NAME" in "Additional sample data" in entry 32 of the "SUBJECT_SAMPLE_FACTORS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the "RAW_FILE_NAME" in "Additional sample data" in entry 34 of the "SUBJECT_SAMPLE_FACTORS" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "3s", for the subsection, "RELAXATION_DELAY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['s', 'ms', 'us', 'μs']. Ignore this when more complicated descriptions are required. Error: The value, "12 kHz", for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required.