Validation Log 2025-12-15 00:22:04.949391 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003483/mwtab/txt Study ID: ST002130 Analysis ID: AN003483 File format: txt Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 3 Number of Value Errors: 3 Number of Consistency Errors: 0 Number of Format Errors: 5 Issue Log: Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "FLOW_RATE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Warning: The "m/z" column at position 4 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Molecular weight" column at position 2 in the METABOLITES table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT (min)" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.