Validation Log 2025-12-15 00:24:05.753450 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003519/mwtab/txt Study ID: ST002149 Analysis ID: AN003519 File format: txt Status: Contains Validation Issues Number of Issues: 15 Number of Warnings: 0 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 7 Issue Log: Error: The value, "Male and female", for the subsection, "GENDER", in the "SUBJECT" section should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "ADDITIVES", in the "COLLECTION" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "INSTRUMENT_TYPE", in the "MS" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "MS_TYPE", in the "MS" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "CHROMATOGRAPHY_SUMMARY", in the "CHROMATOGRAPHY" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "CHROMATOGRAPHY_TYPE", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "INSTRUMENT_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "COLUMN_NAME", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The required property, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "FLOW_RATE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_A", in the "CHROMATOGRAPHY" section is missing. Error: The required property, "SOLVENT_B", in the "CHROMATOGRAPHY" section is missing. Error: The MS_METABOLITE_DATA table does not have a column for "Samples". It is likely misspelled or using a common incorrect substitute. Error: The METABOLITES table does not have a column for "metabolite_name". It is likely misspelled or using a common incorrect substitute.