Validation Log 2025-12-15 00:27:39.986205 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003583/mwtab/txt Study ID: ST002189 Analysis ID: AN003583 File format: txt Status: Contains Validation Issues Number of Issues: 10 Number of Warnings: 0 Number of Value Errors: 9 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "ANIMAL_VET_TREATMENTS", in the "TREATMENT" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The required property, "ANALYSIS_TYPE", in the "ANALYSIS" section is missing. Error: The value, "0.5 mM DSS", for the subsection, "STANDARD_CONCENTRATION", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mM']. Ignore this when more complicated descriptions are required. Error: The value, "799.9", for the subsection, "SPECTROMETER_FREQUENCY", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['MHz']. Ignore this when more complicated descriptions are required. Error: The value, "25 o C", for the subsection, "TEMPERATURE", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C', 'K']. Ignore this when more complicated descriptions are required. Error: The value, "128 scans", for the subsection, "NUMBER_OF_SCANS", in the "NM" section should be a unitless number. Ignore this when more complicated descriptions are required. Error: The value, "9523.8", for the subsection, "SPECTRAL_WIDTH", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm', 'Hz']. Ignore this when more complicated descriptions are required. Error: The value, "None", for the subsection, "BINNED_INCREMENT", in the "NM" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['ppm']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "BINNED_DATA_EXCLUDED_RANGE", in the "NM" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether.