Validation Log 2025-12-15 00:36:13.216836 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003731/mwtab/json Study ID: ST002283 Analysis ID: AN003731 File format: json Status: Contains Validation Issues Number of Issues: 7 Number of Warnings: 3 Number of Value Errors: 7 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "61-91", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "45°C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "5μL", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "300°C", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Warning: The "CalcMz" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "IonFormula" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "formula". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "IonFormula" column at position 8 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 124 C27 H52 O12 N0 P1 169 C36 H70 O10 N0 P1 170 C37 H72 O10 N0 P1 171 C38 H74 O10 N0 P1 172 C38 H74 O10 N0 P1 173 C38 H72 O10 N0 P1 174 C40 H76 O10 N0 P1 175 C39 H74 O10 N0 P1 176 C42 H80 O10 N0 P1 177 C42 H78 O10 N0 P1 178 C43 H80 O10 N0 P1 179 C41 H78 O13 N0 P1 180 C42 H80 O13 N0 P1 181 C43 H80 O13 N0 P1 182 C44 H84 O13 N0 P1 183 C43 H82 O13 N0 P1 184 C47 H82 O13 N0 P1