Validation Log 2025-12-15 00:48:50.578859 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN003978/mwtab/txt Study ID: ST002441 Analysis ID: AN003978 File format: txt Status: Contains Validation Issues Number of Issues: 6 Number of Warnings: 0 Number of Value Errors: 6 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "N2", for the subsection, "COLLISION_GAS", in the "MS" section should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "400°C", for the subsection, "DRY_GAS_TEMP", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "55", for the subsection, "DESOLVATION_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "50", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "8", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required.