Validation Log 2025-12-15 01:12:11.584831 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN004398/mwtab/txt Study ID: ST002713 Analysis ID: AN004398 File format: txt Status: Contains Validation Issues Number of Issues: 5 Number of Warnings: 3 Number of Value Errors: 5 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "see gradient", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "45", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "CalcMz" column at position 2 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "IonFormula" column at position 3 in the METABOLITES table, matches a standard column name, "formula". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "IonFormula" column at position 3 in the METABOLITES table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 45 C27 H45 O0 392 C40 H78 O10 N0 P1 399 C45 H85 O13 N0 P1 Na1 401 C45 H84 O13 N0 P1 403 C45 H83 O13 N0 P1 Na1 404 C45 H82 O13 N0 P1 406 C45 H80 O13 N0 P1 408 C46 H83 O12 N0 P1 Li1 409 C46 H81 O12 N0 P1 Li1 412 C47 H84 O13 N0 P1 563 C27 H43 O0