Validation Log 2025-12-15 01:15:13.958795 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN004456/mwtab/txt Study ID: ST002747 Analysis ID: AN004456 File format: txt Status: Contains Validation Issues Number of Issues: 11 Number of Warnings: 9 Number of Value Errors: 11 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "is 0.6 mL/min.", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "65C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "Average Mz" column at position 3 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "INCHIKEY" column at position 4 in the METABOLITES table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Adduct type" column at position 5 in the METABOLITES table, matches a standard column name, "adduct". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Average Rt(min)" column at position 2 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "INCHIKEY" column at position 4 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Adduct type" column at position 5 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Formula" column at position 6 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Ontology" column at position 7 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "SMILES" column at position 8 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.