Validation Log 2025-12-15 01:25:19.160230 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN004596/mwtab/json Study ID: ST002820 Analysis ID: AN004596 File format: json Status: Contains Validation Issues Number of Issues: 19 Number of Warnings: 12 Number of Value Errors: 16 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "18 and older", in ["SUBJECT"]["AGE_OR_AGE_RANGE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "Male and female", in ["SUBJECT"]["GENDER"] should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["FLOW_GRADIENT"]. A legitimate value should be provided for this required key. Error: The value, "-", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "-", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_A"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_B"]. A legitimate value should be provided for this required key. Warning: The "SUPER PATHWAY" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pathway". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "SUB PATHWAY" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pathway". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PUBCHEM" column at position 10 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 11 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CAS" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "cas_number". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CAS" column at position 9 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "cas_number", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 10 71030-37-0;73837-14-6 42 325465-92-7;799268-65-8 47 542-32-5;1118-90-7 96 1460-34-0;51829-07-3 103 10066-90-7;32113-41-0 180 474-24-9;474-25-9 208 10-2005-9;10417-94-4 213 621890 224 475-31-0;863-57-0 277 5657-19-2;5657-19-2 309 58725-46-5;474943-14-1 314 11-58-0;111-58-0 327 1002-84-2;10002-84-2 357 87-69-4;6106-24-7 376 69-93-2;120K5305 386 59-007 Warning: The "COMP ID" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "other_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CHEMICAL ID" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "other_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RI" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "COMP ID" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "other_id_type", should also exist, and that column was not found. Warning: The column "RI" was found in the ["MS_METABOLITE_DATA"]["Metabolites"] table, but this column implies that another column, "retention_index_type", should also exist, and that column was not found. Warning: The standard column, "other_id", was found in the METABOLITES table as "COMP ID". If this column contains database IDs for standard databases such as KEGG, PubChem, HMDB, etc., it is recommended to make individual columns for these and not lump them together into a less descriptive "other_id" column.