Validation Log 2025-12-15 01:26:27.808989 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN004615/mwtab/json Study ID: ST002827 Analysis ID: AN004615 File format: json Status: Contains Validation Issues Number of Issues: 8 Number of Warnings: 6 Number of Value Errors: 8 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "30°C", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "5µl", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Warning: The "Inchikey" column at position 7 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "inchi_key". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RefMet Name" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem CID" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG" column at position 6 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Method" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "ms_method". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Mode" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "ionization_mode". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.