Validation Log 2025-12-15 01:39:43.360424 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN004787/mwtab/txt Study ID: ST002917 Analysis ID: AN004787 File format: txt Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 5 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 2 Issue Log: Error: An empty value or a null value was detected for the subsection, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, ".52 mL/min helium gas", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "60 ramped to 300", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "SOLVENT_A", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "SOLVENT_B", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "250", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: Unknown or invalid subsection, "SOLVENT_C", in the "CHROMATOGRAPHY" section . Error: Unknown or invalid section, "FACTORS". Warning: The "m/z" column at position 5 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "CAS" column at position 4 in the METABOLITES table, matches a standard column name, "cas_number". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention time" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention index" column at position 2 in the METABOLITES table, matches a standard column name, "retention_index". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The column "Retention index" was found in the METABOLITES table, but this column implies that another column, "retention_index_type", should also exist, and that column was not found.