Validation Log 2025-12-15 01:53:31.866954 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005041/mwtab/json Study ID: ST003083 Analysis ID: AN005041 File format: json Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 10 Number of Value Errors: 12 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "0.150mL/minute", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "25", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "1" column at position 2 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "2" column at position 3 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "7" column at position 8 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "18" column at position 19 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "19" column at position 20 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "20" column at position 21 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "23" column at position 24 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "38" column at position 39 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "39" column at position 40 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "40" column at position 41 in the ["MS_METABOLITE_DATA"]["Data"] table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Error: The ["MS_METABOLITE_DATA"]["Metabolites"] table does not have a column for "Metabolite". It is likely misspelled or using a common incorrect substitute.