Validation Log 2025-12-15 01:57:10.129869 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005117/mwtab/txt Study ID: ST003123 Analysis ID: AN005117 File format: txt Status: Contains Validation Issues Number of Issues: 23 Number of Warnings: 7 Number of Value Errors: 22 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "NA", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: The value, "NA", for the subsection, "WEIGHT_OR_WEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['g', 'mg', 'kg', 'lbs']. Ignore this when more complicated descriptions are required. Error: The value, "NA", for the subsection, "HEIGHT_OR_HEIGHT_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['cm', 'in']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "CELL_PASSAGE_NUMBER", in the "SUBJECT" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "EXTRACT_ENRICHMENT", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "EXTRACT_CLEANUP", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_RESUSPENSION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_DERIVATIZATION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_SPIKING", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "200", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "3600", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "Both", for the subsection, "IONIZATION", in the "MS" section should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: The value, "200", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "FACTORS". Warning: The "quantified m/z" column at position 3 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "parent" column at position 4 in the METABOLITES table, matches a standard column name, "parent_moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "pubchem id" column at position 5 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "kegg id" column at position 6 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "regno" column at position 7 in the METABOLITES table, matches a standard column name, "mw_regno". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 2 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "comments" column at position 8 in the METABOLITES table, matches a standard column name, "comment". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.