Validation Log 2025-12-15 01:59:56.489692 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005164/mwtab/txt Study ID: ST003147 Analysis ID: AN005164 File format: txt Status: Contains Validation Issues Number of Issues: 40 Number of Warnings: 24 Number of Value Errors: 37 Number of Consistency Errors: 2 Number of Format Errors: 1 Issue Log: Error: The value, "60", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "EXTRACT_ENRICHMENT", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "EXTRACT_CLEANUP", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_RESUSPENSION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_DERIVATIZATION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_SPIKING", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "200", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "3600", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "Both", for the subsection, "IONIZATION", in the "MS" section should not be "positive" or "negative". "ION_MODE" is where that should be indicated. Error: The value, "200", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "0.2 ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "FACTORS". Warning: SUBJECT_SAMPLE_FACTORS entry #1 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #2 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #3 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #4 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #5 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #6 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #7 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #8 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #9 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #10 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #11 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #12 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Warning: SUBJECT_SAMPLE_FACTORS entry #13 has the following duplicate keys in its Additional sample data: "RAW_FILE_NAME(Raw File Name)" Error: SUBJECT_SAMPLE_FACTORS section missing sample ID(s). The following IDs were found in the MS_METABOLITE_DATA section but not in the SUBJECT_SAMPLE_FACTORS: "" Warning: The "quantified m/z" column at position 3 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "parent" column at position 4 in the METABOLITES table, matches a standard column name, "parent_moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "pubchem id" column at position 5 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "kegg id" column at position 6 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "regno" column at position 7 in the METABOLITES table, matches a standard column name, "mw_regno". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 2 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "comments" column at position 8 in the METABOLITES table, matches a standard column name, "comment". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: Column(s) with no name were found in the MS_METABOLITE_DATA table. Warning: The "Blank-80MeOH" column at position 2 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Blank-80MeOH_20220211171023" column at position 3 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Blank-80MeOH_20220211180427" column at position 4 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Blank_NoFlow" column at position 5 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Error: The section, MS_METABOLITE_DATA, has a mismatch between the number of headers and the number of elements in each line. Either a line(s) has more values than headers or there are too few headers.