Validation Log 2025-12-15 02:17:15.963832 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005501/mwtab/txt Study ID: ST003359 Analysis ID: AN005501 File format: txt Status: Contains Validation Issues Number of Issues: 10 Number of Warnings: 8 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "0 min, 0.1 ml/min; 8 min, 0.2 ml/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40˚C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "Precursor Ion" column at position 2 in the METABOLITES table, matches a standard column name, "ion". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Product Ion" column at position 3 in the METABOLITES table, matches a standard column name, "ion". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Huh7freshmedia_C30Lip1_oleicd9_1" column at position 2 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Huh7freshmedia_C30Lip1_oleicd9_2" column at position 3 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Huh7freshmedia_C30Lip1_oleicd9_3" column at position 4 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Huh7freshmedia_C30Lip1_elaidicd17_1" column at position 5 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Huh7freshmedia_C30Lip1_elaidicd17_2" column at position 6 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Huh7freshmedia_C30Lip1_elaidicd17_3" column at position 7 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.