Validation Log 2025-12-15 02:18:06.799646 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005517/mwtab/txt Study ID: ST003366 Analysis ID: AN005517 File format: txt Status: Contains Validation Issues Number of Issues: 24 Number of Warnings: 7 Number of Value Errors: 22 Number of Consistency Errors: 1 Number of Format Errors: 1 Issue Log: Error: The required property, "SUBJECT_SPECIES", in the "SUBJECT" section is missing. Error: The value, "20 min", for the subsection, "TREATMENT_DOSEDURATION", in the "TREATMENT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "EXTRACT_ENRICHMENT", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "EXTRACT_CLEANUP", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_RESUSPENSION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_DERIVATIZATION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_SPIKING", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "4500", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "70", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "4500", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "4500", for the subsection, "SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1-5 ul", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Warning: The "compound group name" column at position 2 in the METABOLITES table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "pubchem id" column at position 6 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "kegg id" column at position 7 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "regno" column at position 8 in the METABOLITES table, matches a standard column name, "mw_regno". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "expected retention time" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Error: Column(s) with no name were found in the METABOLITES table. Warning: The "" column at position 9 in the METABOLITES table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Error: The section, METABOLITES, has a mismatch between the number of headers and the number of elements in each line. Either a line(s) has more values than headers or there are too few headers.