Validation Log 2025-12-15 02:23:10.412758 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005602/mwtab/txt Study ID: ST003411 Analysis ID: AN005602 File format: txt Status: Contains Validation Issues Number of Issues: 20 Number of Warnings: 6 Number of Value Errors: 20 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "60", for the subsection, "AGE_OR_AGE_RANGE", in the "SUBJECT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['weeks', 'days', 'months', 'years']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "EXTRACT_ENRICHMENT", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "EXTRACT_CLEANUP", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_RESUSPENSION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_DERIVATIZATION", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: An empty value or a null value was detected for the subsection, "SAMPLE_SPIKING", in the "SAMPLEPREP" section. Either a legitimate value should be provided for this subsection, or it should be removed altogether. Error: The value, "-4500", for the subsection, "CAPILLARY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "70", for the subsection, "DRY_GAS_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['L/hr', 'L/min']. Ignore this when more complicated descriptions are required. Error: The value, "-4500", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "-4500", for the subsection, "SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['kV']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "40", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1-5 ul", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Warning: The "compound group name" column at position 2 in the METABOLITES table, matches a standard column name, "name". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "pubchem id" column at position 6 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "kegg id" column at position 7 in the METABOLITES table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "regno" column at position 8 in the METABOLITES table, matches a standard column name, "mw_regno". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "expected retention time" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "retention time" column at position 4 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.