Validation Log 2025-12-15 02:30:44.246316 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005770/mwtab/txt Study ID: ST003514 Analysis ID: AN005770 File format: txt Status: Contains Validation Issues Number of Issues: 41 Number of Warnings: 38 Number of Value Errors: 41 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: An empty value or a null value was detected for the subsection, "TREATMENT_SUMMARY", in the "TREATMENT" section. A legitimate value should be provided for this required subsection. Error: The value, "0.6mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "50°C", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "mz" column at position 2 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "RT" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Plasma Before Low 2_1-r001" column at position 17 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Low 2_1-r002" column at position 18 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Low 2_2-r001" column at position 19 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Low 2_2-r002" column at position 20 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Low 2_3-r001" column at position 21 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Low 2_3-r002" column at position 22 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_1-r001" column at position 23 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_1-r002" column at position 24 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_2-r001" column at position 25 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_2-r002" column at position 26 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_3-r001" column at position 27 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before Med 2_3-r002" column at position 28 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_1-r001" column at position 29 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_1-r002" column at position 30 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_2-r001" column at position 31 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_2-r002" column at position 32 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_3-r001" column at position 33 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma Before High 2_3-r002" column at position 34 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_1-r001" column at position 35 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_1-r002" column at position 36 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_2-r001" column at position 37 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_2-r002" column at position 38 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_3-r001" column at position 39 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Low 2_3-r002" column at position 40 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_1-r001" column at position 41 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_1-r002" column at position 42 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_2-r001" column at position 43 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_2-r002" column at position 44 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_3-r001" column at position 45 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After Med 2_3-r002" column at position 46 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_1-r001" column at position 47 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_1-r002" column at position 48 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_2-r001" column at position 49 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_2-r002" column at position 50 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_3-r001" column at position 51 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different. Warning: The "Plasma After High 2_3-r002" column at position 52 in the MS_METABOLITE_DATA table may have incorrect values. 90% or more of the values are the same, but 10% or less are different.