Validation Log 2025-12-15 02:34:51.739693 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN005852/mwtab/txt Study ID: ST003561 Analysis ID: AN005852 File format: txt Status: Contains Validation Issues Number of Issues: 18 Number of Warnings: 8 Number of Value Errors: 18 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "280", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "70eV", for the subsection, "IONIZATION_ENERGY", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['eV']. Ignore this when more complicated descriptions are required. Error: The value, "280", for the subsection, "SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "none", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "SOLVENT_A", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "SOLVENT_B", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "60", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "280", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Warning: The "Calc. MW" column at position 2 in the METABOLITES table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "NIST Theo. Mol. Mass" column at position 5 in the METABOLITES table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "NIST Observed Mol. Mass" column at position 6 in the METABOLITES table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "NIST Lib Hit Formula" column at position 4 in the METABOLITES table, matches a standard column name, "formula". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "NIST Lib Hit Formula" column at position 4 in the METABOLITES table, matches a standard column name, "formula", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 8 C12 H15 N O3 10 C19 H19 Cl F N O3 11 C13 H15 N O2 12 C10 H13 N O2 20 C6 H Cl5 O 21 C6 H Cl5 O 27 C11 H11 N O2 33 C7 H15 N O S Warning: The "Analyte Class" column at position 8 in the METABOLITES table, matches a standard column name, "class". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Analyte Class" column at position 8 in the METABOLITES table, matches a standard column name, "class", and some of the values in the column do not match the expected type or format for that column. The non-matching values are: 3 PPCP Warning: The "RT [min]" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.