Validation Log 2025-12-15 02:41:54.436694 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN006011/mwtab/json Study ID: ST003660 Analysis ID: AN006011 File format: json Status: Contains Validation Issues Number of Issues: 13 Number of Warnings: 4 Number of Value Errors: 13 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "72 hours", in ["TREATMENT"]["TREATMENT_DOSEDURATION"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: The value, "High", in ["MS"]["COLLISION_GAS"] should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "55", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-4500V", in ["MS"]["ION_SPRAY_VOLTAGE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "0.3mL/min-0.5mL/min", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "55", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "25μl", in ["CHROMATOGRAPHY"]["SAMPLE_INJECTION"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", in ["CHROMATOGRAPHY"]["INJECTION_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "65 mins", in ["CHROMATOGRAPHY"]["ANALYTICAL_TIME"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Warning: The "Quantified M/z (MS1)" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Quantified M/z (MS2)" column at position 5 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem Identifier" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention time (min)" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.