Validation Log 2025-12-15 02:41:52.990547 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN006011/mwtab/txt Study ID: ST003660 Analysis ID: AN006011 File format: txt Status: Contains Validation Issues Number of Issues: 14 Number of Warnings: 4 Number of Value Errors: 13 Number of Consistency Errors: 0 Number of Format Errors: 1 Issue Log: Error: The value, "72 hours", for the subsection, "TREATMENT_DOSEDURATION", in the "TREATMENT" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['h', 'weeks', 'days']. Ignore this when more complicated descriptions are required. Error: The value, "High", for the subsection, "COLLISION_GAS", in the "MS" section should be one of "Nitrogen" or "Argon". Ignore this when more complicated descriptions are required. Error: The value, "55", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "-4500V", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: The value, "0.3mL/min-0.5mL/min", for the subsection, "FLOW_RATE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "55", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "25μl", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "4", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "65 mins", for the subsection, "ANALYTICAL_TIME", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Error: Unknown or invalid section, "FACTORS". Warning: The "Quantified M/z (MS1)" column at position 4 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Quantified M/z (MS2)" column at position 5 in the METABOLITES table, matches a standard column name, "moverz_quant". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Pubchem Identifier" column at position 2 in the METABOLITES table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "Retention time (min)" column at position 3 in the METABOLITES table, matches a standard column name, "retention_time". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.