Validation Log 2025-12-15 02:52:18.404715 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN006242/mwtab/txt Study ID: ST003797 Analysis ID: AN006242 File format: txt Status: Contains Validation Issues Number of Issues: 14 Number of Warnings: 0 Number of Value Errors: 14 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "1mL/min", for the subsection, "HELIUM_FLOW", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['mL/min']. Ignore this when more complicated descriptions are required. Error: The value, "230℃", for the subsection, "ION_SOURCE_TEMPERATURE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1411V", for the subsection, "ION_SPRAY_VOLTAGE", in the "MS" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['V', 'kV']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "FLOW_GRADIENT", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "90℃-205℃-310℃", for the subsection, "COLUMN_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "1μL", for the subsection, "SAMPLE_INJECTION", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected for the subsection, "SOLVENT_A", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: An empty value or a null value was detected for the subsection, "SOLVENT_B", in the "CHROMATOGRAPHY" section. A legitimate value should be provided for this required subsection. Error: The value, "270°C", for the subsection, "INJECTION_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C'] or "room temperature". Ignore this when more complicated descriptions are required. Error: The value, "29min(leaf); 38min(kernel)", for the subsection, "ANALYTICAL_TIME", in the "CHROMATOGRAPHY" section should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['min']. Ignore this when more complicated descriptions are required. Error: The value, "300℃", for the subsection, "TRANSFERLINE_TEMPERATURE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: The value, "8μL", for the subsection, "WEAK_WASH_VOLUME", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "8μL", for the subsection, "STRONG_WASH_VOLUME", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required. Error: The value, "10μL", for the subsection, "SAMPLE_SYRINGE_SIZE", in the "CHROMATOGRAPHY" section should be a number followed by a space with a unit (ex. "5 V") from the following list: ['μL', 'uL']. Ignore this when more complicated descriptions are required.