Validation Log 2025-12-15 03:02:46.968516 mwtab Python Library Version: 2.0.0 Source: https://www.metabolomicsworkbench.org/rest/study/analysis_id/AN006482/mwtab/json Study ID: ST003943 Analysis ID: AN006482 File format: json Status: Contains Validation Issues Number of Issues: 10 Number of Warnings: 3 Number of Value Errors: 10 Number of Consistency Errors: 0 Number of Format Errors: 0 Issue Log: Error: The value, "Not applicable", in ["SUBJECT"]["GENDER"] should be one of "Male", "Female", "Male, Female", "Hermaphrodite", or "N/A". Ignore this when more complicated descriptions are required. Error: The value, "300", in ["MS"]["ION_SOURCE_TEMPERATURE"] should be a number followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["FLOW_GRADIENT"]. A legitimate value should be provided for this required key. Error: The value, "1ml/min Helium gas", in ["CHROMATOGRAPHY"]["FLOW_RATE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['mL/min', 'uL/min', 'μL/min']. Ignore this when more complicated descriptions are required. Error: The value, "280", in ["CHROMATOGRAPHY"]["COLUMN_TEMPERATURE"] should be a number or range (ex. "5-6") followed by a space with a unit (ex. "5 V") from the following list: ['°C', 'C']. Ignore this when more complicated descriptions are required. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_A"]. A legitimate value should be provided for this required key. Error: An empty value or a null value was detected in ["CHROMATOGRAPHY"]["SOLVENT_B"]. A legitimate value should be provided for this required key. Warning: The "MW" column at position 2 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "mass". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "PubChem CID" column at position 3 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "pubchem_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name. Warning: The "KEGG Compound ID" column at position 4 in the ["MS_METABOLITE_DATA"]["Metabolites"] table, matches a standard column name, "kegg_id". If this match was not in error, the column should be renamed to the standard name or a name that doesn't resemble the standard name.